2013年8月8日星期四

the initial charging knowledge


All electric stacker forklift battery before use, first unscrew the stamp, remove lid sealing holes to keep holes open. Added after cooling the electrolyte, the temperature should not fall below that level or higher than 32 degrees.
Electrolyte surface height should be appropriate in the protection board 15-20 mm, QA added electrolyte dry-charged battery can be used after two hours. As with a very short time or within 12 hours dormant. 5% of the current available capacity for 3-4 hours, the temperature dropped to 30-35 degrees, if the force be used in artificial hot summer cooling, holding time must not exceed 12 hours.
Initial charging charging less strictly prohibited. If insufficient charge will result in permanent battery charger, which can affect battery capacity, have reduced electric forklift battery life, so the initial charging work must be cautious.
4, battery charging full extent of judgment
Electric forklift in the charge state, the specific gravity and electro-hydraulic battery terminal voltage, in three hours or more constant. Plate down evenly bubbles occur, electro-hydraulic there turn slightly milky clear, stop charging capacity after 1 hour with a standard rechargeable 0,1 current value quickly when violent bubbling.the normal battery charging
During charging electric forklift electro-hydraulic temperature not exceeding 45 degrees, otherwise the charge current should be reduced, the stable artificial cooling, or suspend charging, but the beginning of a charged battery within 12 hours from the beginning shall not terminate, and the need to avoid charging is suspended.